Low-pressure steam boilers

The boilers from the KP series are intended for generation of saturated steam with working pressure up to 0,05 МРа and temperature up to 110°С.  

By customer request, different additional equipment items can be offerred, such as containers, water softener installations, fuel oil pump and heating unit when heavy oil is used, as well as gas train (line) for boilers working with nature gas, and others.

See pictures  ► Gallery

Technical charactersitics

No Boiler      type       Rated steam output          Rated heat output             Working pressure Saturated steam temperature Feed water temperature Efficiency    Weight, without auxilliary      equipment
kg/h            Gcal/h
kW
MPa °C °C % kg
1. KP 0,1 171 0,1
116,3
0,05 110 60 92 1144
2. KP 0,15 257 0,15
174,4
0,05 110 60 92 1534
3. KP 0,25 428 0,25
290
0,05 110 60 92 1724
4. KP 0,35 599 0,35
407
0,05 110 60 92 2480
5. KP 0,55 942 0,55
639,6
0,05 110 60 92 2890
6. KP 0,65 1113 0,65
755,9
0,05 110 60 92 3200
7. KP 1,0 1712 1,0
1163